Before you start

Please note that this guide is specifically for the IVT Greenline C, D, E heat pump models featuring an external input panel, typically accessed by removing the front panel. If your heat pump is of a different model, find relevant guides for various models on our website. Additionally, make sure there is a power outlet within two meters of the heat pump and that the Flow is installed within range of a 2.4 GHz Wi-Fi. Carefully follow the steps in this guide to set up the Flow correctly.

Turn off the heat pump before installation. For further information about a specific model, refer to the heat pump's installation manual. Be cautious when handling electrical equipment. If you are unsure at any step, please consult a certified electrician.

image
image

Open the Flow device by pressing both sides together and pulling up the lid.

image
image

Connect cable pair OUT 1 to OUT1: A & B on the Flow circuit board input. OUT2, OUT2, and OUT3 is not used.

Connect the USB adapter cable to the power supply input. Red to + and black to -.

image
image

Attach the Velcro strap to the back of the Flow device and position it next to the heat pump.

image
image

Neatly route the cable(s) behind the heat pump so they are positioned next to the external input panel.

image
image

Disconnect the power for the heat pump. Then connect the Flow cables to the external input board on the heat pump.

For IVT Greenline C, D, E:

Connect OUT1 to EXT.

image
image

On the heat pump’s display, go to meny 5.7 “Comiss./Service” and enable external control “No. 1”.

image
image

Insert the USB adapter into a wall socket to power the Flow device. Confirm the power supply by ensuring that the bottom LED indicator flashes blue.

image
image

Log in to the Perific app using your user account or installer account, then navigate to Settings → Add New Device. Follow the on-screen instructions to connect the Flow device to your Wi-Fi. Once setup is complete, return to the Overview to configure the Flow device. Select your heat pump model from the dropdown list.

No installer account? Go to en.perific.com/register-admin

image
image

Run the Installation Test feature in the app to ensure that the function is operating correctly.

image
image

Installation complete! Control the heat pumps function(s) from the Overview. Activate optiFlow for schedueled or price based heating hours.